Err

Electrochemistry Supplies
Search Your Cart
Testimony Aeroprotec

Aeroprotec


Expert in aeronautic coatings

OrigaSens - Platinum grid counter-electrode
Platinum grid counter-electrode
  • Use: Counter-electrode, corrosion
  • Length: 152 mm
  • Basket diameter: 32 mm
OrigAccess - OrigaSwitch, foot control
Foot control to start and stop the rotation of a rotating electrode:
  • Socket: SUB-D 9 plug
  • Cable length: 2m (modifiable on request)
  • Pedal dimension: 10 cm x 7 cm

OrigaTrod - RDE brush
Spare part for OrigaTrod
Multiplexeur - OrigaMux

MULTIPLEXEUR ELECTROCHIMIQUE
ORIGAMUX

DESCRIPTION
Concept OrigaMux
Spécifications techniques
Consulter la brochure
Projet EASCVsens
MULTIPLIEZ VOS RECHERCHES !
> Obtenez jusqu'à 72 cellules pour un instrument de mesure
> Programmez vos méthodes sur une multitude de cellules
 
MODE ZRA :
> Maintien du potentiel à 0 V
> Reprise du ZRA automatique en cas de coupure électrique/courant
 
APPLICATIONS :
> Surveillance de corrosion
> Test inhibiteur de corrosion
> Corrosion galvanique
> Traitement de surface
> Pile à combustible
> Pile microbienne
> Electrolyseur
ORIGAMUX
ORIGAMUX
 
 
> La gamme OrigaFlex est un système multi-voies (multi-potentiostats) flexible, modulaire, compacte et unique sur le marché. 
 
> Vous pouvez commencer votre système avec une simple voie (mono-voie), pour ensuite l'étendre sans limite grâce à sa connexion Ethernet.
 
> Pour fonctionner, votre potentiostat doit être connecté à une voie "pilote" (OGFDRV), qui fait office de "chassis".
 
> Selon votre configuration, pilotez votre appareil avec notre logiciel OrigaMaster 5 en USB ou avec notre logiciel OrigaViewer en ETHERNET.  Individuellement, chaque voie se contrôle en USB, par OrigaMaster 5. Simultanément, chaque voie se pilote via ETHERNET, par OrigaViewer. 
Principales spécifications
OrigaMux
Nombre de cellules
 
Entrées commutées 
 
Disponibiltés
 
Type de commutation
 
Entrée d'impédance
 
En cascade
 
Gamme de courant
 
Maintien du potentiel
 
Sécurité contre les coupures de courant en mode ZRA
 
Communication
 
Connecteurs
 
Logiciel
8 cellules par MUX
 
WRK + (REF | REF2 | AUX | TEMP + GND)
 
01A / 10A
 
Relais
 
10GΩ 20pF
 
Possibilité d'avoir 9 OrigaMux en cascade, permettant d'avoir jusqu'à 72 canaux
 
Du pA à 10A par cellules selon l'OGF connecté
 
15 V ±100mA en 2/3/4 électrodes
 
Oui
 
Piloté par OGFDRV (éthernet)
 
1 connecteur 6 points +2 SMB par celulle
 
OrigaViewer 2

PROJET EASCVSENS

Voltamétrie par échantillonnage de courant sur un réseau d'électrodes pour la détection des éléments-traces métalliques dans les eaux.
 
Partenaires : 
SATIE LOGO
BRGM logo
Instrument industriel de terrain - OrigaCorr

Instrument industriel de terrain - ORIGACORR
Appareil tout-en-un, effectuez des mesures et stockez les résultats

DESCRIPTION
Logiciels de pilotage
Spécifications techniques
Consulter la brochure
Projet SCCODRA
Analysez soignement le taux de corrosion in situ !
> Appareil robuste - résistant et durable : Protection contre les chocs, la poussière et les jets d'eau
> Facilement transportable
> Facile à utiliser : Appareil autonome (mesure sans ordinateur)
> Mémoire étendue (14 500 résultats en mémoire volatile)
 
Appareil tout-en-un, effectuez des mesures et stockez les résultats
> Configurez et exportez la sécurité de vos données.
> Obtenez des mesures précises et fiables du taux de corrosion.
> Mesurez le taux de corrosion sur une large gamme de matériaux et de surface.
> Méthode non destructive
> Calcul exact et précis du coefficient B de Stern et Geary utilisé pour calculer le taux de corrosion
> Interconnexion entre les méthodes
> MODE ZRA : Redémarrage automatique en cas de panne de courant

Méthodes applicables :
> Spectroscopie d'impédance électrochimique (EIS)
> Potentiel de circuit ouvert (OCP)
> Résistance de polarisation linéaire (LPR)
> Analyse de distorsion harmonique (HDA) :
 
Applications :
> Corrosion générale
> Corrosion galvanique
ORIGAcorr
Deux modes de fonctionnement : 
 
> Pilotez votre OrigaCorr avec notre logiciel OrigaMaster, en mode classique
OrigaCorr
 
 
 
 
> Configuration par organigramme
> Choix complet de chaque paramètre pour chaque méthode
OrigaCorr
 
 
 
 
> Traitement post-analyse
OrigaCorr
 
 
 
 
> Courbes disponibles
> Pilotez votre OrigaCorr avec notre logiciel OrigaCorrField, en mode automatique
OrigaCorr
 
 
 
 
> Rapide et facile à régler
> Configuration guidée
OrigaCorr
 
 
 
 
> Exécution automatique de la mesure
OrigaCorr
 
 
 
 
> Exportez vos résultats avec Excel
Principales spécifications
OrigaCorr
Electrodes
 
Potentiel max appliqué
 
Tensions de sortie
 
Courant maximum
 
Gammes de courant
 
Impédance (EIS)
 
Logiciel PC
 
Précision en potentiel
 
Précision en courant
 
Résolution en courant
 
Impédance d'entrée
 
Bande passante
 
Interface
2,3 et 4
 
±5V
 
±17.5V
 
±100mA
 
±1nA à ±100mA en 9 décades
 
10 µHz à 1 KHz
 
OrigaMaster 5 (en mode manuel) / OrigaCorrFiled (en mode automatique)
 
<0.1% FSR (Pleine échelle)
 
< 0.1% FSR
 
0.003% FSR (Meilleure : 30 fA)
 
1 TΩ (//20pF)
 
1MHz
 
USB 2.0

PROJET SCCoDRa

Surveillance et Contrôle des composants métalliques pour le stockage des Déchets Radioactifs
Développement de techniques innovantes de contrôle et de monitoring de la corrosion de composants métalliques
Projet SCCoDRa
Kit de polissage pour embouts
375.00 EUR (EU only)

KIT DE POLISSAGE POUR EMBOUTS
Optimisez vos mesures 

DESCRIPTION
Fonctionnement
A découvrir aussi
Effectuez des mesures fiables & précises en optant pour notre kit de polissage pour embouts.
 
> Optimisation de la sensibilité
> Uniformisation de la surface
> Réduction des interférences
> Réduction des effers de bord
 
Ce kit comprend :
> Un support de polissage en Acier 
> 20 disques de polissage : 5 x P1200 + 5 x P600 + 5 x Satin + 5 x Feutre
> 3 flacons d'alumines : 1 x 2-3 µm +  1 x 1 µm + 1 x 0.3µm
 
> Ils peuvent être utilisés avec l'électrode tournante (OrigaTrod) et le support d'électrode (StaTrod).
> Composition : PEEK
> Diamètre extérieur : 11 mm
> Longueur : 20 mm
 
Nous contacter pour plus d'informations concernant les embouts suivants : Chrome (Cr), Irridium (Ir), Palladium (Pd), Rhodium (Rh), Cobalt (Co) ou pour tout autres matériaux. 
Multiplexer - OrigaMux

ELECTROCHEMICAL MULTIPLEXER
ORIGAMUX

DESCRIPTION
OrigaMux Concept
Technical specifications
Consult the brochure
EASCVsens Project
MULTIPLY YOUR RESEARCH!
> Get up to 72 cells for one measuring instrument
> Program your methods on a multitude of cells
 
ZRA MODE :
> Potential maintained at 0 V
> Automatic resumption of ZRA in the event of a power/current failure
 
APPLICATIONS :
> Corrosion monitoring
> Corrosion inhibitor testing
> Galvanic corrosion
> Surface treatment
> Fuel cell
> Microbial cell
> Electrolyser
ORIGAMUX
ORIGAMUX
 
> The OrigaFlex range is a flexible, modular, compact multi-potentiostat system that is unique on the market. 
 
> You can start your system with a single channel, then expand it without limit thanks to its Ethernet connection.

> To operate, your potentiostat must be connected to a “driver” channel (OGFDRV), which acts as a “chassis”.

> Depending on your configuration, you can control your device with our OrigaMaster 5 software via USB or with our OrigaViewer software via ETHERNET.  Individually, each channel can be controlled via USB using OrigaMaster 5 and simultaneously via ETHERNET using OrigaViewer. 
Main specifications
OrigaMux
Number of cells

Switched inputs 

Availability

Type of switching

Impedance input

Cascaded

Current range

Potential hold

Safety against power failure in ZRA mode

Communication

Connectors

Software
8 cells per MUX

WRK + (REF | REF2 | AUX | TEMP + GND)

01A / 10A

Relay

10GΩ 20pF

Possibility of cascading 9 OrigaMux, giving up to 72 channels

From pA to 10A per cell depending on the OGF connected

15 V ±100mA in 2/3/4 electrodes

Yes

Controlled by OGFDRV (Ethernet)

1 6-pin connector +2 SMB per cell

OrigaViewer 2

PROJET EASCVSENS

Voltammetry using current sampling on an electrode array to detect trace metals in water.

Partners : 
SATIE LOGO
BRGM logo
All-in-one device, take measurements and store results

Configure and export your data security.
 
Obtain accurate and reliable corrosion rate measurements.
 
Measure corrosion rates on a wide range of materials and surfaces.



OrigaCell - Stand + Thermostated Cell
820.00 EUR (EU only)
Stand for Glass Cell
  • Thermostated: Yes
  • Sealed: No
  • Volume: 150 ml
  • Cell included: Yes
  • Exchengeable cell: Yes
OrigaCell - Stand + Cell
525.00 EUR (EU only)
Stand for Glass Cell
  • Thermostated: No
  • Sealed: No
  • Volume: 150 ml
  • Cell included: Yes
  • Exchengeable cell: Yes
pH-meter for Industry - OpH228

pH-meter for Industry - Easy Pack
OpH228

DESCRIPTION
USE
Included in the Pack
Technical specifications
Expert and profesional pH-meter for Industry
 
> Inherited from Radiometer PHM220 (same designer)
> Can be integrated into an existing pH meter fleet because its interface is compatible with those of old Radiometer pH meters.
 
> Easy connections
> Reliable and fast results
> Data transfer (Regressi, Excel and ExAo)
> Has an easy to use interface
> Durable and with a 5-year warranty (excluding consumables)
 
> Measurement history (quality control - customizable measurements)
> Menu BPL (Bonnes Pratiques de Laboratoire) : traçabilité des mesures
 
OpH228
Operation of this bench pH meter & OrigaLys laboratory
 
Calibration:
> The instructions are simple and in French on a large display. The pH meter calibration menu allows you to choose to calibrate on 1-3 points from two sets of buffers (IUPAC or 4-7-10). Another calibration mode exists: the free mode, it allows you to dip the electrode and adjust the value of the buffer with the arrows provided for this purpose, this calibration is performed on two buffers. If desired, you can use the calibration parameters of the last manipulation.
 
Data transfer:
> Lthese parameters of the latest calibrations are stored in the instrument and can be exported to a. txt file via USB transfer. The pH meter is compatible with almost all Ex.A.O. systems (Regressi included) thanks to its outputs (digital and analog). Measured data can be exported, only, in real time:
> USB to Excel
> By RS232 to acquisition cards (software Regressi for example)
> Par analogique vers des cartes d'acquisitions
 
Measurement Modes
> Two measurement modes are available to facilitate the operator’s work: manual mode, which allows a continuous reading of the pH by displaying the stability indicator or automatic mode where the result freezes when the signal is stabilized (100% stability).
 
Connecting the electrodes
> The electrode connections allow you to use the probes of your choice (all brands) with the appropriate cable: the single or combined electrode connected to a BNC plug and the reference electrode connected with a 4 mm banana plug (if necessary). The temperature probe is connected via a CINCH input. Without a probe, you are free to manually enter the temperature on the main display of the pH meter.
Composition of the Easy pack OpH228
 
This simple pack includes:
> The pH-meter 
> A power supply EURO (AR00863)
 
Main specifications
OpH228
pH Measure range
 
mV Measure range
 
°C Measure range
 
pH Resolution
 
mV Resolution
 
°C Resolution
 
Calibration
 
Calibration acceptance criteria
(modifiable and customizable)
 
 
 
Measure
- 9 to 23 pH
 
 ± 2000 mV

 - 10°C to 110°C

 ± 0,01 pH

 ± 0,1 mV
 
 ± 0,1 °C

 1 to 4 buffers (automatic / free by adjustment / manual)

Default settings:
Slope: 95 to 102%
Zero-pH: 5.80 to 7.50 pH
Non-blocking criteria generating a warning
 
Continue, automatique ou à intervalles
OrigaSens - Filling solution 3M KCl
35.00 EUR (EU only)

Filling Solution 
- 3 mol/l KCl, saturated Ag/AgCl 
- 250 mL for Reference electrodee Ag/AgCl or salt bridge
OrigaSens - Filling Solution saturated KCl
35.00 EUR (EU only)

Filling Solution 
- saturated KCl
- 250 mL for reference electrode Hg
Origaccess - UHF-S7 1 m Cord
60.00 EUR (EU only)

UHF-S7 1m cord
Origaccess - BNC-Banana ø2 Black 1m Cord
65.00 EUR (EU only)

Cordon BNC-Banana ø2
- Black
- 1m
Origaccess - BNC-Banana ø2 Red 1m Cord
65.00 EUR (EU only)

Cordon BNC-Banana ø2
- Red
- 1m
Origaccess - Swagelok Cell Type - 3 electrodes Ø 12.7 mm
545.00 EUR (EU only)

Swagelok Cell:
- 3 electrodes
- T shape
545.00 EUR (EU only)

Swagelok cell:
- 3 electrodes
- T shape
Origaccess - Swagelok Cell - 2 electrodes Ø 12.7 mm
375.00 EUR (EU only)

Swagelok cell:
- 2 electrodes
- Straight shape
375.00 EUR (EU only)

Swagelok cell:
- 2 electrodes
- Straight shape
OrigaCell - Corrosion Cell (Flow Cell)
Corrosion Cell for Flow Corrosion 
Thermostated: Yes
Waterproof: Oui
Volume: 230 ml
Active area: 1.33 cm²
OrigaSens - Voltammetry Electrode Platinum Plate 8x8 120mm
390.00 EUR (EU only)

Metal Electrode Platinum Plate 8x8 mm
Use: Voltammetry, Auxiliary Electrode, counter-electrode
Length: 103mm
Higher diameter: 12mm
Lower diameter: 8mm
OrigaSens - Voltammetry Electrode Platinum Disc Ø10 103mm
270.00 EUR (EU only)

Metal electrode, Platinum Disc 10mm
Use: Voltammetry, auxiliary electrode, counter-electrode
Length: 103mm
Diameter: 12mm
OrigaMeter - Bench pH-meter OpH218 - Glass Combined Pack

Combined Pack:
  • pH-meter
  • One Combined pH electrode in Glass
  • One cable
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV
OrigaMeter - Bench pH-meter OpH218 - Epoxy Combined Pack

Combined Pack:
  • pH-meter
  • One Combined pH electrode in Epoxy
  • One cable
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV
OrigaMeter - Bench pH-meter OpH218 - Calomel Non-combined Pack

Non-combined Pack:
  • pH-meter
  • One Non-combined pH electrode
  • One Calomel Reference electrode (SCE)
  • Two cables
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV
OrigaMeter - Bench pH-meter OpH218 - Ag/AgCl Non-combined Pack

Non-combined Pack:
  • pH-meter
  • One Non-combined pH electrode
  • One Ag/AgCl Reference electrode
  • Two cables
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV
OrigaMeter - Bench pH-meter OpH218 - Simple Pack

Simple Pack:
  • pH-meter
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV
Testimony Lycée du Parc

Lycée du Parc - Lyon - Preparatory Classes for Engineer School


Luc Martel, professor in Chemistry.



Potentiostat de terrain :

En savoir plus sur le fonctionnement



The versatil Bipotentiostat:

Mode details on how it works

OrigaLine - Battery Cord - 3m
60.00 EUR (EU only)

Long distance cord for Batteries
  • 3m
  • For OrigaFlex


Potentiostat All in One:

More details on how it works



Potentiostat for the field:

More details on how it works

Testimony IUT Besançon

Chimistry Department - IUT Besançon 


Marie-Laure Doche, internship manager, 2° study director.

OrigaFlex - OGF10A pack

Single-potentiostat system

  • Potentiostat and Galvanostat (OGF10A)
  • Its Power Supply (OGFPWR)
  • Connection cables
  • PC software OrigaMaster 5
  • Maximum current: ±10 A
OrigaFlex - OGF01A pack

Single-potentiostat system
  • Potentiostat and Galvanostat (OGF01A)
  • Its Power Supply (OGFPWR)
  • Connection cables
  • Its PC software, OrigaMaster 5
  • Maximum current: ±1 A
OrigaFlex - OGF05A pack

Mono-potentiostat system
  • Potentiostat and Galvanostat (OGF05A)
  • Its Power Supply (OGFPWR)
  • Connection cables
  • Its PC software, OrigaMaster 5
  • Maximum current: ±5 A
OrigaStat - OGS100

OrigaStat OGS100
  • Potentiostat
  • Galvanostat
  • Impedancemeter
  • pH-meter
  • Temperature probe
  • Speed Controller for RDE
  • Control of external devices
  • 17V and 100mA
OrigaStat - OGS200

OrigaStat OGS200
  • Potentiostat
  • Galvanostat
  • Impedancemeter
  • pH-meter
  • Temperature probe
  • Speed Controller for RDE
  • Control of external devices
  • 35V 2A USB
OrigaStat - OGS080+ with OrigaCell Kit

OrigaStat - OGS080+
  • Potentiostat
  • Galvanostat
  • Impedancemeter
  • Speed Controller for RDE
  • Built-in Electrochemical Cell (OrigaCell Kit)
  • 17V 100mA USB
OrigaStat - OGS100+ with OrigaCell Kit

OrigaStat OGS100+
  • Potentiostat
  • Galvanostat
  • Impedancemeter
  • pH-meter
  • Temperature probe
  • Speed Controller for RDE
  • Control of external devices
  • Built-in Electrochemical Cell (OrigaCell Kit)
  • 17V 100mA USB
OrigaStat - OGS200+ with OrigaCell Kit

OrigaStat OGS200+
  • Potentiostat
  • Galvanostat
  • Impedancemeter
  • pH-meter
  • Temperature probe
  • Speed Controller for RDE
  • Control of external devices
  • Built-in Electrochemical Cell (OrigaCell Kit)
  • 35V 2A USB
OrigaStat - Teaching Pack

Single-potentiostat system dedicated to teaching
  • Potentiostat and Galvanostat (OGS080)
  • With Built-in impedance
  • Connection cables
  • OrigaMaster 5 PC software
  • Maximum current: ±100 mA
 
Newsletter OrigaLys
last updates and special offers
Subscribe to our newsletter.

paiement sécurisé
100% Secured Payment
Check our different payment methods
paiement sécurisé
Fast Delivery
Delivery Methods Details
paiement sécurisé
+33 (0)9 54 17 56 03
paiement sécurisé
Linkedin
Facebook
Instagram
Youtube