Aeroprotec
Expert in aeronautic coatings
|
| Platinum grid counter-electrode
- Use: Counter-electrode, corrosion
- Length: 152 mm
- Basket diameter: 32 mm
|
|
Foot control to start and stop the rotation of a rotating electrode:
- Socket: SUB-D 9 plug
- Cable length: 2m (modifiable on request)
- Pedal dimension: 10 cm x 7 cm
|
|
| MULTIPLEXEUR ELECTROCHIMIQUE ORIGAMUXDESCRIPTION Concept OrigaMux Spécifications techniques Consulter la brochure Projet EASCVsens MULTIPLIEZ VOS RECHERCHES !
> Obtenez jusqu'à 72 cellules pour un intrusment de mesure
> Programmez vos méthodes sur une multitude de cellules
MODE ZRA :
> Maintien du potentiel à 0 V > Reprise du ZRA automatique en cas de coupure électrique/courant
APPLICATIONS :
> Surveillance de corrosion
> Test inhibiteur de corrosion
> Corrosion galvanique
> Traitement de surface
> Pile à combustible
> Pile microbienne
> Electrolyseur
> La gamme OrigaFlex est un système multi-voies (multi-potentiostats) flexible, modulaire, compacte et unique sur le marché.
> Vous pouvez commencer votre système avec une simple voie (mono-voie), pour ensuite l'étendre sans limite grâce à sa connexion Ethernet.
> Pour fonctionner, votre potentiostat doit être connecté à une alimentation (OGFPWR) ou une voie "pilote" (OGFDRV), qui fait office de "chassis".
> Selon votre configuration, pilotez votre appareil avec notre logiciel OrigaMaster 5 en USB ou avec notre logiciel OrigaViewer en ETHERNET. Individuellement, chaque voie se contrôle en USB, par OrigaMaster 5. Simultanément, chaque voie se pilote via ETHERNET, par OrigaViewer. Principales spécifications Nombre de cellules
Entrées commutées
Disponibiltés
Type de commutation
Entrée d'impédance
En cascade
Gamme de courant
Maintien du potentiel
Sécurité contre les coupures de courant en mode ZRA
Communication
Connecteurs
Logiciel 8 cellules par MUX
WRK + (REF | REF2 | AUX | TEMP + GND)
01A / 10A
Relais
10GΩ 20pF
Possibilité d'avoir 9 OrigaMux en cascade, permettant d'avoir jusqu'à 72 canaux
Du pA à 10A par cellules selon l'OGF connecté
15 V ±100mA en 2/3/4 électrodes
Oui
Piloté par OGFDRV (éthernet)
1 connecteur 6 points +2 SMB par celulle
OrigaViewer 2 PROJET EASCVSENSVoltamétrie par échantillonnage de courant sur un réseau d'électrodes pour la détection des éléments-traces métalliques dans les eaux.
Partenaires : |
| Instrument industriel de terrain - ORIGACORR Appareil tout-en-un, effectuez des mesures et stockez les résultats
DESCRIPTION Logiciels de pilotage Spécifications techniques Consulter la brochure Projet SCCODRA Analysez soignement le taux de corrosion in situ !
> Appareil robuste - résistant et durable : Protection contre les chocs, la poussière et les jets d'eau > Facilement transportable > Facile à utiliser : Appareil autonome (mesure sans ordinateur) > Mémoire étendue (14 500 résultats en mémoire volatile)
Appareil tout-en-un, effectuez des mesures et stockez les résultats > Configurez et exportez la sécurité de vos données. > Obtenez des mesures précises et fiables du taux de corrosion. > Mesurez le taux de corrosion sur une large gamme de matériaux et de surface. > Méthode non destructive > Calcul exact et précis du coefficient B de Stern et Geary utilisé pour calculer le taux de corrosion > Interconnexion entre les méthodes > MODE ZRA : Redémarrage automatique en cas de panne de courant
Méthodes applicables : > Spectroscopie d'impédance électrochimique (EIS) > Potentiel de circuit ouvert (OCP) > Résistance de polarisation linéaire (LPR)
> Analyse de distorsion harmonique (HDA) :
Applications :
> Corrosion générale
> Corrosion galvanique Deux modes de fonctionnement :
> Pilotez votre OrigaCorr avec notre logiciel OrigaMaster, en mode classique
> Configuration par organigramme
> Choix complet de chaque paramètre pour chaque méthode
> Traitement post-analyse > Pilotez votre OrigaCorr avec notre logiciel OrigaCorrField, en mode automatique
> Rapide et facile à régler > Configuration guidée
> Exécution automatique de la mesure
> Exportez vos résultats avec Excel Principales spécifications Electrodes
Potentiel max appliqué
Tensions de sortie
Courant maximum
Gammes de courant
Impédance (EIS)
Logiciel PC
Précision en potentiel
Précision en courant
Résolution en courant
Impédance d'entrée
Bande passante
Interface 2,3 et 4
±5V
±17.5V
±100mA
±1nA à ±100mA en 9 décades
10 µHz à 1 KHz
OrigaMaster 5 (en mode manuel) / OrigaCorrFiled (en mode automatique)
<0.1% FSR (Pleine échelle)
< 0.1% FSR
0.003% FSR (Meilleure : 30 fA)
1 TΩ (//20pF)
1MHz
USB 2.0 PROJET SCCoDRaSurveillance et Contrôle des composants métalliques pour le stockage des Déchets Radioactifs Développement de techniques innovantes de contrôle et de monitoring de la corrosion de composants métalliques |
|
KIT DE POLISSAGE POUR EMBOUTS Optimisez vos mesures
DESCRIPTION Fonctionnement A découvrir aussi Effectuez des mesures fiables & précises en optant pour notre kit de polissage pour embouts.
> Optimisation de la sensibilité
> Uniformisation de la surface
> Réduction des interférences
> Réduction des effers de bord
Ce kit comprend :
> Un support de polissage en Acier > 20 disques de polissage : 5 x P1200 + 5 x P600 + 5 x Satin + 5 x Feutre > 3 flacons d'alumines : 1 x 2-3 µm + 1 x 1 µm + 1 x 0.3µm
> Ils peuvent être utilisés avec l'électrode tournante (OrigaTrod) et le support d'électrode (StaTrod).
> Composition : PEEK > Diamètre extérieur : 11 mm > Longueur : 20 mm Nous contacter pour plus d'informations concernant les embouts suivants : Chrome (Cr), Irridium (Ir), Palladium (Pd), Rhodium (Rh), Cobalt (Co) ou pour tout autres matériaux. |
| OrigaLys Multiplexer - OrigaMux
Hold your potentials on all your cells and take current measurements sequentially.
|
|
All-in-one device, take measurements and store results
Configure and export your data security.
Obtain accurate and reliable corrosion rate measurements.
Measure corrosion rates on a wide range of materials and surfaces.
|
|
Filling Solution
- 3 mol/l KCl, saturated Ag/AgCl
- 250 mL for Reference electrodee Ag/AgCl or salt bridge
|
|
Filling Solution
- saturated KCl
- 250 mL for reference electrode Hg
|
| |
Cordon BNC-Banana ø2
- Black
- 1m
|
|
Cordon BNC-Banana ø2
- Red
- 1m
|
|
Swagelok Cell:
- 3 electrodes
- T shape
|
|
Swagelok cell:
- 3 electrodes
- T shape
|
|
Swagelok cell:
- 2 electrodes
- Straight shape
|
|
Swagelok cell:
- 2 electrodes
- Straight shape
|
|
Corrosion Cell for Flow Corrosion
Thermostated: Yes
Waterproof: Oui
Volume: 230 ml
Active area: 1.33 cm² |
|
Metal Electrode Platinum Plate 8x8 mm
Use: Voltammetry, Auxiliary Electrode, counter-electrode
Length: 103mm
Higher diameter: 12mm
Lower diameter: 8mm
|
|
Metal electrode, Platinum Disc 10mm
Use: Voltammetry, auxiliary electrode, counter-electrode
Length: 103mm
Diameter: 12mm
|
|
Combined Pack:
- pH-meter
- One Combined pH electrode in Glass
- One cable
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV
|
|
Combined Pack:
- pH-meter
- One Combined pH electrode in Epoxy
- One cable
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV |
|
Non-combined Pack:
- pH-meter
- One Non-combined pH electrode
- One Calomel Reference electrode (SCE)
- Two cables
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV
|
|
Non-combined Pack:
- pH-meter
- One Non-combined pH electrode
- One Ag/AgCl Reference electrode
- Two cables
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV |
|
Range of pH measure: - 9 to 23 pH
Range of mV measure: ± 2000 mV
|
|
Lycée du Parc - Lyon - Preparatory Classes for Engineer School
Luc Martel, professor in Chemistry.
|
|
Potentiostat de terrain :
En savoir plus sur le fonctionnement |
|
The versatil Bipotentiostat:
Mode details on how it works |
|
Long distance cord for Batteries
|
|
Potentiostat All in One:
More details on how it works |
|
Potentiostat for the field:
More details on how it works |
|
Chimistry Department - IUT Besançon
Marie-Laure Doche, internship manager, 2° study director.
|
|
Single-potentiostat system
- Potentiostat and Galvanostat (OGF10A)
- Its Power Supply (OGFPWR)
- Connection cables
- PC software OrigaMaster 5
- Maximum current: ±10 A
|
|
Single-potentiostat system
- Potentiostat and Galvanostat (OGF01A)
- Its Power Supply (OGFPWR)
- Connection cables
- Its PC software, OrigaMaster 5
- Maximum current: ±1 A
|
|
Mono-potentiostat system
- Potentiostat and Galvanostat (OGF05A)
- Its Power Supply (OGFPWR)
- Connection cables
- Its PC software, OrigaMaster 5
- Maximum current: ±5 A
|
|
OrigaStat OGS100
- Potentiostat
- Galvanostat
- Impedancemeter
- pH-meter
- Temperature probe
- Speed Controller for RDE
- Control of external devices
- 17V and 100mA
|
|
OrigaStat OGS200
- Potentiostat
- Galvanostat
- Impedancemeter
- pH-meter
- Temperature probe
- Speed Controller for RDE
- Control of external devices
- 35V 2A USB
|
|
OrigaStat - OGS080+
- Potentiostat
- Galvanostat
- Impedancemeter
- Speed Controller for RDE
- Built-in Electrochemical Cell (OrigaCell Kit)
- 17V 100mA USB
|
|
OrigaStat OGS100+
- Potentiostat
- Galvanostat
- Impedancemeter
- pH-meter
- Temperature probe
- Speed Controller for RDE
- Control of external devices
- Built-in Electrochemical Cell (OrigaCell Kit)
- 17V 100mA USB
|
|
OrigaStat OGS200+
- Potentiostat
- Galvanostat
- Impedancemeter
- pH-meter
- Temperature probe
- Speed Controller for RDE
- Control of external devices
- Built-in Electrochemical Cell (OrigaCell Kit)
- 35V 2A USB
|
|
Single-potentiostat system dedicated to teaching
- Potentiostat and Galvanostat (OGS080)
- With Built-in impedance
- Connection cables
- OrigaMaster 5 PC software
- Maximum current: ±100 mA
|
|
Single-potentiostat system dedicated to Coatings
- Potentiostat and Galvanostat (OGS200)
- With Built-in Impedance
- Connection cables
- OrigaMaster 5 PC Software
- Maximum current: ±2 A
|
|
BNC-BNC 1m Cord
Necessary cord to connect the OrigaBox to a potentiostat Metrohm-Autolab.
|
|
BNC-SUB D9 2.5m Cord
Necessary cord to connect the OrigaBox to an other potentiostat.
|
|
BNC-BNC 5m Cord
Necessary cord to connect the OrigaBox to a potentiostat from Metrohm-Autolab.
|
|
BNC female / 2 sockets Banana female Ø4
Necesary to connect electrode (or rotating disk electroded) to an other potentiostat.
|
|
Stand for Glass Cell
- Thermostated: Yes
- Sealed: Yes
- Volume: 250 ml
- Cell included: Yes
- Exchengeable cell: Yes
|
|
Reference Electrode Calomel
Length: 103mm
Higher Diameter: 12mm
Lower Diameter: 8mm
Electrolyte: 1 M LiCl
Similar to REF921
|
|
Gold microelectrode 10 µm
Length: 50 mm
Internal Diameter: 10 µm
External Diameter: 5 mm
|
|
Gold microelectrode 25 µm
Length: 50 mm
Internal diameter: 25 µm
External diameter: 5 mm
|
|
Gold microelectrode 40 µm
Longueur : 50 mm
Diamètre intérieur : 40 µm
Diamètre extérieur : 5 mm
|
|
Gold microelectrode 50 µm
Length: 50 mm
Internal Diameter: 50 µm
External Diameter: 5 mm
|
|
Gold microelectrode 100 µm
Length: 50 mm
Internal Diameter: 100 µm
External Diameter: 5 mm
|
|
Gold microelectrode 200 µm
Length: 50 mm
Internal Diameter: 200 µm
External Diameter: 5 mm
|
|
Platinum microelectrode 10 µm
Length : 50 mm
Internal diameter : 10 µm
External diameter : 5 mm
|
|
Platinum microelectrode 25 µm
Length : 50 mm
Internal diameter : 25 µm
External diameter : 5 mm
|
|
Platinum Microelectrode 50 µm
Length : 50 mm
Internal Diameter : 50 µm
External Diameter : 5 mm
|
|
Platinum microelectrode 100 µm
Length : 50 mm
Internal diameter : 100 µm
External diameter : 5 mm
|
|
Platinum microelectrode 200 µm
Length : 50 mm
Internal diameter : 200 µm
External diameter : 5 mm
|
|